wall mounted domestic disinfect chemical reactor
Basic Info
Model No.: CPF-C
Product Description
Place of Origin: Jiangsu, China (Mainland)
Model Number: CPF-C
Certification: ISO9001, CE Marked
EINECS No. 233-162-8
CAS NO. 10049-04-4
Control: Automatic
Model: Wall-mounted
Power: Electric
Structure:
Main parameters:
Working temperature: 5 ~ 40 degrees Celsius Operating voltage: 220V plus or minus 10% Operating current: <10A There should be no strong electric field and magnetic field interference around equipment. Maximum pressure of water-pipe-line: <0.7Mpa Function: linkage with water pump, low liquid level alarm, flow / residual clo2 control, or manual control, auto start/stop locally, remote start/stop, work data upload
Components:
5 NaClO2 + 4HCl = 4ClO2 + 5NaCl + 2H2O
NaClO2: industrial sodium chlorite (purity≥78% )
Activator: industrial first grade compound hydrochloric acid (purity≥31%) or other weak acid or strong acid
Conversions Rate of ClO2=98%≥95%
Test Result:
Test Equipment:
Packed with wooden cases or as your demand.
Shipped by EXW, FOB, C&F, CFR, CIF, etc, or as your demand. With photos before shipment.
Free design of the engineering project.
Free training to your personnel of the generator`s operation and maintenance.
Quality guarantee for one year.
Remote video direction to the problem within 24 hours.
Contact us if you need more details on Chemical Reactor. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Disinfect Chemical Reactor、Wall Mounted Reactor. If these products fail to match your need, please contact us and we would like to provide relevant information.